Alternating control relay for two electric pumps – RAL 202 RED

Desde (sem IVA): 51,00

Alternating Relay – 2 pumps – Alarm + Lack water

O envio apenas é disponibilizado para Portugal Continental e suas respetivas Regiões Autónomas: Açores e Madeira.

Descrição do produto

Alternating relay for alternating control of two electropumps, control of lack of water in the supply network and output for alarm.
Control signals by closing contact, pressure switch and internal timing
Alternating voltage for water-tight probe


Applications

  • Control signals by closing contact, pressure switch and internal timing
  • Alternating voltage for water supply probe

Operation

Power the relay (green led on – A.1)

Two sec. after closing the pair of contacts “P1” (5-6), it requires the operation of an electric pump. If the pair of contacts “P2” (7-6) closes, two sec. then they will force the operation of the other electric pump. The electric pumps in operation will turn off inversely, respectively “P2” and “P1”.

When the “P1” pair closes again, the first electric pump to start will be the next in the alternation sequence. Terminal 1 is common to relay outputs 3, 9 and 11, for motor control and alarm, respectively.

Whenever the “FA” – lack of water control (4-6) remains open, the “F.A.” is lit, the electric pumps can be activated by the commands “P1”, “P2”. When closing the “FA” – lack of water command (4-6), the “F.A.” flashes (1 sec), indicates lack of water, if any electric pump, or both, are activated, after 20 seconds, the electric pump control contacts disarm, after 3 min., in this condition the alarm sets (1 -3).

Failure of the contact pairs: If “P1” remains open and “P2” closes, the electric pumps will be activated, the alarm will arm (1-3), when “P2” opens, the electric pumps will turn off together with the alarm.

When the PA contact pair (6-8) closes, it sets the alarm and indicates that the minimum or maximum pressure switches have been activated.

Note:
The PA input does not interfere with the normal operation of the devices.

The images shown may not correspond completely to the product described.

Informação adicional

Peso 240 g
Dimensões (C x L x A) 11 × 8,5 × 5,3 cm
Tensão para sonda de nível / bóia

24V AC

Temperatura ambiente

[-10ºC, +55ºC]

Relé de saída

AC 8A-250V / 50Hz – 1250VA DC 5A-24 V (C.R.)

Alimentação

AC (230V, 400V) / 50Hz

Consumo

2VA (approx.)

Tensão

230V AC, 400V AC

Encaixe

11-pin base